Customization: | Available |
---|---|
Function: | Steam Boilers |
Fuel: | Waste Heat |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Waste heat boiler belongs to non-standard product, which usually needs to be calculated and designed according to the parameters provided by customers. Generally speaking, the design pressure of non-combustion waste heat boiler is 0.2-2.5 Mpa, the working pressure is 0.4-2.5 Mpa, and the steam output is 0.2-25 t/h. Some waste heat boiler technical parameters as following: |
||||
Specification | Q5-940-2-1.0 | Q16-900-6-1.25 | Q20-1050-9-2.5 | Q32-800-11-1.6 |
Rated evaporation capacity(t/h) | 2 | 6 | 9 | 11 |
Rated working pressure(MPa) | 1 | 1.25 | 2.5 | 1.6 |
Rated steam temperature(ºC) | 184 | 250 | 226 | 204 |
Water-supply temperature(ºC) | 20 | 20 | 125 | 20 |
Inlet flue gas flow rate(Nm³/h) | 5000 | 16000 | 20800 | 32000 |
Inlet flue gas temperature(ºC) | 940 | 900 | 1050 | 800 |
Outlet flue gas temperature(ºC) | 385 | 164 | 371 | 179.9 |
Heating area(m2) | 171.79 | 536.1 | 345 | 916.6 |
Boiler Installation Size L×W×H (mm) |
6200×3440×8419 | 8035×3500×4390 | 12262×2680×4860 | 10500×3050×4150 |
A | Its industry | |
B | Flue gas parameters | |
1 | Boiler inlet flue gas side pressure | |
2 | Boiler inlet flue gas range (operating conditions) | |
3 | Range of boiler inlet flue gas (standard condition) | |
4 | Design value of boiler inlet flue gas (standard condition) | |
5 | Boiler inlet flue gas temperature range | |
6 | Design value of boiler inlet flue gas temperature | |
7 | Boiler outlet flue gas temperature | |
8 | Boiler inlet flue gas composition (volume percentage) | |
CO | ||
SO2 | ||
SO3 (if any) | ||
CO2 | ||
H2O | ||
O2 | ||
N2 | ||
HCL (if any) | ||
Other special gases | ||
8 | Boiler inlet flue gas dust concentration | |
Boiler inlet flue gas adhesion | ||
Corrosiveness of boiler inlet flue gas | ||
9 | Required resistance on the flue gas side of the boiler body | |
10 | Total air leakage requirements on the boiler flue gas side (if any) | |
C | Boiler parameters | |
1 | Boiler rated steam (if any) | |
2 | Boiler rated steam pressure | |
3 | Boiler rated steam temperature | |
4 | Boiler feedwater temperature | |
D | Other required parameters | |
1 | Elevation and size of smoke exit of industrial furnace | |
2 | Elevated smoke outlet elevation of waste heat boiler | |
3 | Waste heat boiler is expected to occupy land (length m × width m × height m) | |
4 | Does the waste heat boiler need to be supplied by the manufacturer to support the top rain shelter? | |
5 | Boiler layout (vertical or horizontal layout) | |
6 | Owned plant's own compressed air pressure | |
7 | Whether the owner's plant has its own natural gas source | |
8 | Meteorological conditions at the owner's plant (mainly local atmospheric pressure and seismic fortification intensity) | |
E | Auxiliary machine | |
F | Other special requirements |